Zone 0 is the strip within 5 feet of your house, and the fence and gate that cross it. California's rule asks for noncombustible fencing there for homes in the State Responsibility Area and local Very High Fire Hazard Severity Zones. Now is the time to plan the change instead of adding more wood.

What changes

Same fence. Different last five feet.

Illustrative images, not real installations.

See it drawn

The first 5 feet of your fence

If a wood fence or gate touches your house, only the first 5 feet has to change. Everything past that can stay wood.

The 5 foot noncombustible fence spanTop view of a house corner and its side yard. Zone 0 is the 5 foot band around the house. A side-yard fence runs out from the side wall of the house at a right angle to the property line, with a gate next to the house that swings open into the backyard. Under the state Zone 0 rule (14 CCR 1298.04(b)(9); 1299.03(d)(9)), a fence or gate attached to the house, or within 1 foot of it, must be noncombustible for the first 5 feet, measured along the fence from the house. Here that is the wall post, the metal gate, the latch post and a short metal filler, ending at a metal post 5 feet from the wall. The wood fence past 5 feet can stay, and it can be repaired with wood. The property-line fence runs parallel to the side of the house, more than 5 feet away, so it can be wood. Three close-ups show where the 5 feet start. Attached: the fence meets the wall end-on, and the span starts at the wall. Within 1 foot: the fence stops just short of the wall; it counts as attached, and the span starts at the fence end closest to the house. Parallel: a fence 3 feet from the wall runs alongside the house inside Zone 0. No new combustible fence may be built within 5 feet of the house after the rule takes effect; an existing wood one there can stay. Existing homes get 3 to 5 years to replace the attached part.Side-yard fence with a gate, top viewHouseZone 00 to 5 ft aroundthe houseProperty lineFront yardBackyardMetal gateMetalWoodZone 0Property lineFirst 5 ft along the fence,measured from the wall:metal wall post, gate,latch post and filler.Past 5 ft, wood can stay.Repairs in wood are allowed.Property-line fence:more than 5 ft from thehouse, so wood is fine.Where the 5 ft startsAttachedMeets the wall end-on.The 5 ft starts at the wall.Gap under 1 ftWithin 1 ftStops just short of the wall.Counts as attached. The 5 ftstarts at the fence end.Parallel, within 5 ftA new fence here must benoncombustible. An existingwood one can stay.Top view. The 5 ft is measured along the fence, starting at the house.The 5 foot noncombustible fence spanTop view of a house corner and its side yard. Zone 0 is the 5 foot band around the house. A side-yard fence runs out from the side wall of the house at a right angle to the property line, with a gate next to the house that swings open into the backyard. Under the state Zone 0 rule (14 CCR 1298.04(b)(9); 1299.03(d)(9)), a fence or gate attached to the house, or within 1 foot of it, must be noncombustible for the first 5 feet, measured along the fence from the house. Here that is the wall post, the metal gate, the latch post and a short metal filler, ending at a metal post 5 feet from the wall. The wood fence past 5 feet can stay, and it can be repaired with wood. The property-line fence runs parallel to the side of the house, more than 5 feet away, so it can be wood. Three close-ups show where the 5 feet start. Attached: the fence meets the wall end-on, and the span starts at the wall. Within 1 foot: the fence stops just short of the wall; it counts as attached, and the span starts at the fence end closest to the house. Parallel: a fence 3 feet from the wall runs alongside the house inside Zone 0. No new combustible fence may be built within 5 feet of the house after the rule takes effect; an existing wood one there can stay. Existing homes get 3 to 5 years to replace the attached part.Side-yard fence, top viewHouseZone 00 to 5 ftProperty lineFront yardBackyardMetal gateMetalWoodZone 0Property lineFirst 5 ft along the fence, from thewall: metal wall post, gate, latchpost and filler.Past 5 ft, wood can stay.Repairs in wood are allowed.Property-line fence: more than 5 ftfrom the house, so wood is fine.Where the 5 ft startsAttachedMeets the wallend-on. The 5 ftstarts at the wall.Gap under 1 ftWithin 1 ftStops just short ofthe wall. Counts asattached. The 5 ftstarts at its end.Parallel, in 5 ftA new one must benoncombustible.Existing woodcan stay.Top view. The 5 ft is measured along thefence, starting at the house.

The first 5 feet of fence from the house must be noncombustible. The rest can stay wood.

See the rule details
The three zones around a house0 to 5 ft, 5 to 30 ft, 30 to 100 ft
Zone 0, Zone 1 and Zone 2 around a houseTop view of a house with three bands around it, measured out from the building (14 CCR 1299.03(a)). Zone 0, from 0 to 5 feet, is the ember-resistant zone: no bark mulch, firewood or other combustible material, and no wood fence attached at the wall. Zone 1, from 5 to 30 feet: remove dead plants, leaves and needles, and keep branches 10 feet from chimneys. Zone 2, from 30 to 100 feet: space shrubs and trees apart and cut grass to 4 inches or less. A scale line runs out from the house wall through the three bands, marked at 5, 30 and 100 feet. Each zone stops at the property line. Not to scale.HouseZone 2Zone 1Zone 05 ft30 ft100 ftZone 0: 0 to 5 ftEmber-resistant zone.No bark mulch, firewood orwood fence at the wall.Zone 1: 5 to 30 ftRemove dead plants, leavesand needles. Keep branches10 ft from chimneys.Zone 2: 30 to 100 ftSpace shrubs and trees apart.Cut grass to 4 in or less.Not to scale. Each zone stops at the property line.Zone 0, Zone 1 and Zone 2 around a houseTop view of a house with three bands around it, measured out from the building (14 CCR 1299.03(a)). Zone 0, from 0 to 5 feet, is the ember-resistant zone: no bark mulch, firewood or other combustible material, and no wood fence attached at the wall. Zone 1, from 5 to 30 feet: remove dead plants, leaves and needles, and keep branches 10 feet from chimneys. Zone 2, from 30 to 100 feet: space shrubs and trees apart and cut grass to 4 inches or less. A scale line runs out from the house wall through the three bands, marked at 5, 30 and 100 feet. Each zone stops at the property line. Not to scale.HouseZone 2Zone 1Zone 05 ft30 ft100 ftZone 0: 0 to 5 ftEmber-resistant zone. No bark mulch,firewood or wood fence at the wall.Zone 1: 5 to 30 ftRemove dead plants, leaves and needles.Keep branches 10 ft from chimneys.Zone 2: 30 to 100 ftSpace shrubs and trees apart.Cut grass to 4 in or less.Not to scale. Each zone stops at the property line.

California’s three defensible space zones, measured out from the house.

See the rule details
When each part is dueDay 1, year 3, year 3 to 5
Zone 0 deadlines for new and existing homesTwo lanes. New homes, meaning a building permit application submitted after the effective date: every Zone 0 requirement applies from the day the rule takes effect. Existing homes (14 CCR 1298.04(c); 1299.03(e)): on day 1, keep the roof and gutters clear, remove dead branches, keep branches 10 feet from chimney outlets and out from under eaves, and build no new wood or other combustible fence or gate within 5 feet. Within 3 years: remove combustible mulch, leaves and debris, firewood and anything that burns under decks and stairs, remove ladder fuels and keep branches 5 feet above the roof. Within 3 to 5 years: create the plant-free strips, bring other plants within the limits, give attached fences and gates a 5 foot noncombustible span, and make sheds in Zone 0 noncombustible or move them. In local Very High Fire Hazard Severity Zones the local fire agency sets 3 years or up to 5; in the State Responsibility Area it is 5 years or a CAL FIRE Director timeline of at least 3. Day 1 is the date the state rule takes effect.Day 1Within 3 yearsWithin 3 to 5 yearsThe rule takes effectNew homesPermit applied for after day 1Every Zone 0 requirement applies from day 1Existing homesRoof and gutters clearNo dead branchesBranches 10 ft fromchimney outletsNo branches under eavesNo new wood fence orgate within 5 ftNo mulch, leaves ordebris in Zone 0No firewood in Zone 0Nothing that burns underdecks and stairsLadder fuels removedBranches 5 ft above roofPlant-free strips at walls,windows, doors and decksOther plants within limits5 ft noncombustible spanon attached fences, gatesSheds noncombustibleor out of Zone 0Day 1 is the date the state rule takes effect.Within 3 to 5 years: the local fire agency sets the date in local Very High zones;the CAL FIRE Director sets it in the State Responsibility Area (SRA).Zone 0 deadlines for new and existing homesTwo lanes. New homes, meaning a building permit application submitted after the effective date: every Zone 0 requirement applies from the day the rule takes effect. Existing homes (14 CCR 1298.04(c); 1299.03(e)): on day 1, keep the roof and gutters clear, remove dead branches, keep branches 10 feet from chimney outlets and out from under eaves, and build no new wood or other combustible fence or gate within 5 feet. Within 3 years: remove combustible mulch, leaves and debris, firewood and anything that burns under decks and stairs, remove ladder fuels and keep branches 5 feet above the roof. Within 3 to 5 years: create the plant-free strips, bring other plants within the limits, give attached fences and gates a 5 foot noncombustible span, and make sheds in Zone 0 noncombustible or move them. In local Very High Fire Hazard Severity Zones the local fire agency sets 3 years or up to 5; in the State Responsibility Area it is 5 years or a CAL FIRE Director timeline of at least 3. Day 1 is the date the state rule takes effect.New homesEvery Zone 0 requirementapplies from day 1Permit applied for after day 1Existing homesDay 1: the rule takes effectRoof and gutters clearNo dead branchesBranches 10 ft from chimney outletsNo branches under eavesNo new wood fence or gate within 5 ftWithin 3 yearsNo mulch, leaves or debris in Zone 0No firewood in Zone 0Nothing that burns under decks and stairsLadder fuels removedBranches 5 ft above roofWithin 3 to 5 yearsPlant-free strips at walls, windows,doors, vents and decksOther plants within limits5 ft noncombustible span onattached fences and gatesSheds noncombustible or out of Zone 0Day 1 is the date the state rule takes effect.The 3 to 5 year date is set by the local fireagency in local Very High zones, or by theCAL FIRE Director in the SRA.

When each Zone 0 requirement applies, counted from the day the rule takes effect.

See the rule details
Aerial view of a house with a gravel band around the walls and a black metal fence

What to do now

Four steps for your fence and gate

  1. MeasureMark 5 feet out from the wall. Count every fence and gate that touches the house or comes within 1 foot of it.
  2. Hold offDo not build a new wood or vinyl fence or gate within 5 feet of the house. New ones are barred there from the day the state rule takes effect.
  3. PlanPrice a noncombustible section, metal or masonry, for the first 5 feet at each spot where a fence meets the house.
  4. AskAsk your insurer what a clear 5 foot zone, fences and gates included, is worth on your policy.